Induction and circuits
A transformer
Two coils sharing one magnetic flux: an alternating current in the first makes the flux change, and the change induces a voltage in every turn of the second. Count the turns and you change the voltage.
Before you look
Predict first: The primary has 100 turns and the secondary 300. The primary gets 10 V. What does the secondary give?
What you are looking at
A 100-turn coil inside a 300-turn coil, driven at 5 kHz (slowed ten thousand times). Voltmeter V₁ reads the primary, V₂ the secondary across a 1 kΩ load.
Both coils glow and their currents reverse together each half cycle.
The physics
If every turn of both coils links the same flux Φ, each turn has the same EMF, so
In general the coupling is the mutual inductance M. With the secondary open the ratio is exactly , which falls short of by the leakage: here against 3. A load draws current and pulls V₂ down a little more; the lab’s check uses the full circuit,
Going deeper
Vector calculus and Maxwell’s equations
The coupling coefficient measures how much flux is shared; an iron core brings k to 0.999 by giving the flux an easy closed path. Power transformers run at 50 Hz with iron; at 5 kHz in air the coils’ reactance ωL is large enough that the magnetising current stays small.
What to measure
V₂/V₁ against coupled-coil theory and N₂/N₁
- Read V₁ and V₂ and divide: about 2.77.
- Change the secondary’s turns to 100: the ratio drops to a little under 1.
- Change the load to 10 Ω: V₂ falls as the secondary’s own reactance takes its share.
What the model leaves out
- There is no iron anywhere: every coil here has an air core.
- Coils, rings and magnets are filament loops, each standing for a bundle of turns or a slice of a magnet’s surface current. Very close to a loop the field is a little lumpy; a few loop spacings away it is exact.
- Wires are perfect conductors with no inductance of their own, and nothing radiates: the circuit is lumped, which is right while it is much smaller than a wavelength.
Things to try
- Pull the secondary off the primary sideways (drag it while the clock runs): V₂ falls as the coupling drops.
- Swap the roles: drive the 300-turn coil and the 100-turn one steps the voltage down.
References
- D. J. Griffiths (2017), Introduction to Electrodynamics, 4th edition, Cambridge University Press.
- E. M. Purcell and D. J. Morin (2013), Electricity and Magnetism, 3rd edition, Cambridge University Press.
- P. Horowitz and W. Hill (2015), The Art of Electronics, 3rd edition, Cambridge University Press.
More experiments, and how the lab works, are in the lab’s overview.