Capacitors and dielectrics
The coaxial cable
A coaxial cable is a rod inside a tube. Between them the field points straight out and falls as 1/r, and the potential falls as ln r. The cable’s capacitance per metre depends only on the ratio of the radii: that is why cables of very different sizes can have the same impedance.
Before you look
Predict first: You double both radii. What happens to the capacitance per metre?
What you are looking at
A rod 10 cm across at 1 V inside a grounded tube of inner radius 19 cm.
The physics
is the charge per metre on the rod, its radius and the tube’s inner radius.
Going deeper
Vector calculus and Maxwell’s equations
A real cable’s impedance is : 50 Ω cables have about 3.5 with polythene inside.
What to measure
C = 2πε₀/ln(b/a) per metre
- The check reads the charge per metre on the rod at 1 V.
What the model leaves out
- The insulator between the conductors; set it with a dielectric tube.
Things to try
- Move the rod off centre: the field crowds on the near side.
References
- D. J. Griffiths (2017), Introduction to Electrodynamics, 4th edition, Cambridge University Press.
More experiments, and how the lab works, are in the lab’s overview.